E 30 to EI 120

Fire-Rated Glazed Screens

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

E 30EI 120

Get a free survey or quote

Tell us what you need. We reply with next steps and a guide price.

Full-height glazed screen with a glazed door between a school corridor and a classroom

What does our fire-rated glazed screens service include?

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Survey and setting-out against the fire strategy drawings
  • Steel, aluminium, timber or frameless frame systems
  • Integrity or insulating glass to the required classification
  • Integrated fire doors and glazed doorsets
  • Fire-stopping at head, jambs and sill to the system details
  • Handover evidence pack

What should you check before ordering?

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Integrity-only screens on escape routes

Building guidance limits where integrity-only glazing can sit on protected escape routes, and in some positions restricts it to above a set height from the floor. Insulating screens are not restricted in the same way, so the route plan often decides the glass.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Acoustic and security needs

Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

What evidence do you get?

  • System test or assessment reference (BS EN 1364-1 / BS EN 13501-2)
  • Shop drawings with pane sizes and glass schedule
  • Fixing and fire-stopping details
  • Installation photographs and installer's completion record

Guide prices for fire-rated glazed screens

Framed screens typically £550–£1,400/m² supplied and installed, depending on frame and rating, excluding VAT. Prices depend on the rating, pane sizes, frame system, access and programme. Use the guide price tool for a range, or see all guide prices.

Frequently asked questions

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Related services

Often specified alongside fire-rated glazed screens

Process

How we deliver fire-rated glazed screens

Tell us what you need

Send sizes, the rating required, photos of glass marks or your inspection report.

Survey

We measure, record existing marks and check frames, substrates and fire-stopping.

Written quote

Your quote names the tested system, classification and evidence it relies on.

Install and hand over

Installed to the system details, then a handover pack with photographs and references.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote