Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Timber fire-rated screens are glazed partitions made with hardwood frames, glazing beads and intumescent seals that have been tested together to resist fire. They are common in schools, healthcare, heritage buildings and residential blocks where a warmer finish is wanted.
Tell us what you need. We reply with next steps and a guide price.

The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.
Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.
Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.
Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Timber screens typically £550–£1,000/m² supplied and installed, excluding VAT. Prices depend on the rating, pane sizes, frame system, access and programme. Use the guide price tool for a range, or see all guide prices.
Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.
Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.

Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →
Doorsets with large glazed panels, tested as complete units.
Learn more →
Internal glazed screens that keep compartments and corridors protected.
Learn more →
Replacement and new vision panels fitted to the door's evidence.
Learn more →Select your county or region for local coverage, towns and the rules that apply there.
Send sizes, the rating required, photos of glass marks or your inspection report.
We measure, record existing marks and check frames, substrates and fire-stopping.
Your quote names the tested system, classification and evidence it relies on.
Installed to the system details, then a handover pack with photographs and references.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.