Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
Tell us what you need. We reply with next steps and a guide price.

We supply and install glazed fire doorsets in timber, steel and aluminium, single and double, as stand-alone doors or within glazed screens. We match the door to the rating and duty of its position, and fit it to the manufacturer's installation instructions.
The safest route is a complete doorset with frame and hardware tested together. Mixing a leaf from one source with a frame from another needs evidence that covers the combination.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Self-closing devices and correct gaps are part of the performance. We set them at installation and record them.
Opening forces, vision panel zones and contrast need to work with accessibility guidance as well as fire.
Residential blocks in England over 11 metres need regular fire door checks under the Fire Safety (England) Regulations 2022; glazed doors are included.
Glazed fire doorsets typically from £950 per single door supplied and installed, excluding VAT. Prices depend on the rating, pane sizes, frame system, access and programme. Use the guide price tool for a range, or see all guide prices.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Yes, some steel, aluminium and timber doorsets are tested with large or full-height glazing. The glass must be the type and size in the evidence.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
Yes. They need fire-resistant glass of the type and thickness tested, fitted with the specified beads and seals.

Replacement and new vision panels fitted to the door's evidence.
Learn more →
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →
Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →
Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Select your county or region for local coverage, towns and the rules that apply there.
Send sizes, the rating required, photos of glass marks or your inspection report.
We measure, record existing marks and check frames, substrates and fire-stopping.
Your quote names the tested system, classification and evidence it relies on.
Installed to the system details, then a handover pack with photographs and references.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.