Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
England · 60 postcode districts

Fire-Rated Glazed Screens in Devon

Fire-rated glazed screens across Devon covers 60 postcode districts in the EX, TQ, PL, DT postcode areas. Every job is built around a tested system.

E 30 – EI 120EnglandEXTQPL

Quote for Devon

Tell us what you need. We reply with next steps and a guide price.

Full-height glazed screen with a glazed door between a school corridor and a classroom

Fire-Rated Glazed Screens: an overview for Devon

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Fire-stopping at head, jambs and sill to the system details
  • Integrity or insulating glass to the required classification
  • Integrated fire doors and glazed doorsets

Before you order in Devon

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Acoustic and security needs

Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.

Choose a town in Devon

We cover fire-rated glazed screens in Plymouth and across Devon, including Exeter, Paignton, Torquay, Newton Abbot.

Which rules apply in England?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Questions from Devon clients

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Do you cover all of Devon?

Yes. We take enquiries from across Devon, including Plymouth and Exeter, Paignton, Torquay, Newton Abbot, and arrange surveys to suit your programme.

Related

Related services in Devon

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Devon and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote