Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
Tell us what you need. We reply with next steps and a guide price.

These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Fanlight and side panel re-glazing from £220 per panel supplied and fitted, excluding VAT. Prices depend on the rating, pane sizes, frame system, access and programme. Use the guide price tool for a range, or see all guide prices.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.

Replacement and new vision panels fitted to the door's evidence.
Learn more →
Hardwood screens and borrowed lights tested for fire.
Learn more →
Putting right the defects found in surveys and fire risk assessments.
Learn more →
Replace old Georgian wired glass with modern fire glass.
Learn more →Select your county or region for local coverage, towns and the rules that apply there.
Send sizes, the rating required, photos of glass marks or your inspection report.
We measure, record existing marks and check frames, substrates and fire-stopping.
Your quote names the tested system, classification and evidence it relies on.
Installed to the system details, then a handover pack with photographs and references.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.