How is fire-rated glazing tested and classified?

Furnace tests, classification reports and assessments explained.

Fire-rated glazing is tested by building a full-size sample of the glazed system into a furnace wall and heating one side to a standard time-temperature curve while integrity, radiation and insulation are measured. The results are turned into a classification under BS EN 13501-2, such as EI 60, which applies only to the tested system within its field of application.

Which test standards apply?

Glazed screens and non-loadbearing walls are typically tested to BS EN 1364-1. Doors and opening windows are tested to BS EN 1634-1. The results are classified to BS EN 13501-2.

Older UK evidence may refer to BS 476 Part 22. In England, references to the British Standard route are being phased out of Approved Document B, so check what evidence your project will accept.

What happens in the test?

A specimen built exactly as it will be installed is mounted in a furnace. One side is heated following the standard fire curve, which passes about 840°C after 30 minutes and about 1,000°C after 90 minutes.

Thermocouples, radiometers and gap gauges record performance until the specimen fails or the test ends.

What is a field of application?

Test results can be applied to variations of the tested specimen, such as different sizes or orientations, only within rules set by the standards or by an assessment from a competent test body. Outside those limits the evidence does not cover the installation.

What is an assessment?

Where a project differs from what was tested, a fire test laboratory or competent body can issue an assessment, sometimes called a global or engineering assessment, which states whether the variation would be expected to achieve the classification. Assessments are a normal part of fire glazing evidence.

What should you receive?

Ask for the classification report or certificate covering the system, any assessments relied on, and the installation instructions. We include these references in every handover pack.

Updated 09/10/2026. General guidance only; your fire strategy, designer and building control body decide what applies to a specific building.

Services

Related services

Full-height glazed screen with a glazed door between a school corridor and a classroom
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Surveyor with a tablet and torch inspecting the frame edge of a glazed screen
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Gloved hands setting a thick laminated glass pane onto setting blocks in a grey steel glazing frame
E 30 – EI 120

Fire-Resistant Glass

Integrity and insulating fire glass supplied and fitted into tested frames.

Learn more →

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote