Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
England · 1 postcode district

Fire-Rated Glazed Screens in Rutland

Our Rutland fire-rated glazed screens service covers survey, supply and installation to the tested details, documented on handover.

E 30 – EI 120EnglandLE

Quote for Rutland

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens: an overview for Rutland

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

  • Fire-stopping at head, jambs and sill to the system details
  • Steel, aluminium, timber or frameless frame systems
  • Integrity or insulating glass to the required classification

Before you order in Rutland

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Acoustic and security needs

Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.

Regulations for Rutland projects

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Places we cover in Rutland

Rutland coverage includes Oakham, Uppingham and the LE postcode areas (1 postcode district).

Questions from Rutland clients

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

Do you cover all of Rutland?

Yes. We take enquiries from across Rutland, including Oakham and Uppingham, and arrange surveys to suit your programme.

Related

Related services in Rutland

Process

How a Rutland job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Rutland and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote