Fire-Rated Glazed Screens across Essex
We survey, supply and install fire-rated glazed screens across Essex, from Southend-on-Sea to Basildon, Colchester, Chelmsford, Harlow, working to the classification your fire strategy sets.
Quote for Essex
Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens: what you get in Essex
A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.
- Integrated fire doors and glazed doorsets
- Integrity or insulating glass to the required classification
- Fire-stopping at head, jambs and sill to the system details
Before you order in Essex
What the screen is fixed to matters
Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.
Acoustic and security needs
Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.
Building control
New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.
Fire-Rated Glazed Screens by town in Essex
Essex coverage includes Southend-on-Sea, Basildon, Colchester, Chelmsford, Harlow and the CM, SS, CO, RM postcode areas (70 postcode districts).
Which rules apply in England?
England Which rules apply?
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire-Rated Glazed Screens in Essex: questions
Can you add a screen to an occupied building?
Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.
How large can a fire-rated glazed screen be?
It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.
Do fire-rated screens need maintenance?
They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.
Can you survey anywhere in Essex?
Yes. We can arrange surveys anywhere in Essex, including Southend-on-Sea and Basildon, Colchester, Chelmsford, Harlow.
Related services in Essex
Aluminium Fire-Rated Screens
Aluminium screens in Southend-on-Sea and nearby
View details →What happens next
Start with the brief
Tell us the rating required, sizes and building type, or ask us to find out.
Measure and check
We measure each opening in Essex and check what the existing frames can accept.
Written quote
You receive a written quote naming the tested system and classification.
Complete and document
Work is completed to the manufacturer's details and documented for your records.