Fanlights, Side Panels & Borrowed Lights
Fanlights & side panels in Woking and nearby
View details →Timber fire-rated screens across Surrey covers 57 postcode districts in the GU, KT, RH, TW postcode areas. Every job is built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Surrey coverage includes Woking, Guildford, Esher, Redhill, Staines-upon-Thames and the GU, KT, RH, TW postcode areas (57 postcode districts).
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.
Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.
Yes. We can arrange surveys anywhere in Surrey, including Woking and Guildford, Esher, Redhill, Staines-upon-Thames.
Fanlights & side panels in Woking and nearby
View details →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Surrey and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.