Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · E14

Frameless Fire-Rated Glazing in Canary Wharf, Greater London

Frameless fire-rated glazing in Canary Wharf is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

E 30 – EI 60E14England

Quote for Canary Wharf

Tell us what you need. We reply with next steps and a guide price.

What our frameless fire-rated glazing service includes in Canary Wharf

Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.

  • Manifestation design
  • Rated sealant joints
  • Tested butt-jointed insulating or integrity glass systems
  • Frameless-look fire doors where tested

Key checks for Canary Wharf projects

Height and corners

Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.

Protection on site

Frameless glass is exposed during the build. We plan protection until other trades finish.

Deflection

Channels at the head have to allow for slab movement without loading the glass.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Canary Wharf coverage and nearby towns

Coverage around Canary Wharf includes the E14, SE16, E3, E1W, E1, SE8 districts and nearby Bow, Canning Town, Greenwich. We cover Canary Wharf as part of our Greater London coverage.

What every Canary Wharf quote includes

Rated systems, not just rated glass

Every quote in Canary Wharf identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Canary Wharf building types

Frameless fire-rated glazing applies to many building types in Canary Wharf, including student accommodation and healthcare buildings.

Questions about frameless fire-rated glazing in Canary Wharf

How tall can frameless fire glass go?

Each system states a maximum height. We check your floor-to-ceiling height against it during design.

Is frameless fire-rated glass possible?

Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.

Which rules apply to fire-rated glazing in Canary Wharf?

Building work in Canary Wharf follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Do you work on occupied buildings in Canary Wharf?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Canary Wharf

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Canary Wharf confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote