Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · E14

Fire-Rated Glazed Screens for Canary Wharf buildings

If a building in Canary Wharf needs fire-rated glazed screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 120E14England

Quote for Canary Wharf

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated glazed screens service includes in Canary Wharf

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Survey and setting-out against the fire strategy drawings
  • Integrated fire doors and glazed doorsets
  • Steel, aluminium, timber or frameless frame systems
  • Integrity or insulating glass to the required classification

What you can expect in Canary Wharf

Work around occupied buildings

We can phase work in Canary Wharf around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Canary Wharf identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Canary Wharf budgets are not open-ended.

What to check before ordering fire-rated glazed screens in Canary Wharf

Integrity-only screens on escape routes

Building guidance limits where integrity-only glazing can sit on protected escape routes, and in some positions restricts it to above a set height from the floor. Insulating screens are not restricted in the same way, so the route plan often decides the glass.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Where we work around Canary Wharf

We cover Canary Wharf and the surrounding postcode districts, including E14, SE16, E3, E1W, E1, SE8. Nearby towns we also serve include Bow, Canning Town, Greenwich. Canary Wharf is one of the Greater London districts we cover.

Which rules apply to fire-rated glazed screens in Canary Wharf?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Canary Wharf

Fire-rated glazed screens applies to many building types in Canary Wharf, including public buildings and offices.

Fire-Rated Glazed Screens: Canary Wharf questions

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

Which rules apply to fire-rated glazing in Canary Wharf?

Building work in Canary Wharf follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

How quickly can you survey in Canary Wharf?

Survey timing in Canary Wharf depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Canary Wharf

Process

How a Canary Wharf job runs

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Canary Wharf confirms sizes, access, existing evidence and fixing conditions.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote