Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →From the E14 district outwards, we arrange fire-rated glazed doors for buildings across Canary Wharf, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
We can phase work in Canary Wharf around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Canary Wharf budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
The safest route is a complete doorset with frame and hardware tested together. Mixing a leaf from one source with a frame from another needs evidence that covers the combination.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Opening forces, vision panel zones and contrast need to work with accessibility guidance as well as fire.
Survey visits can be arranged anywhere in Canary Wharf, including the E14, SE16, E3, E1W, E1, SE8 districts, and in nearby Bow, Canning Town, Greenwich. Canary Wharf sits within our Greater London coverage, alongside Bow.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, student accommodation and other buildings in Canary Wharf.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Yes, some steel, aluminium and timber doorsets are tested with large or full-height glazing. The glass must be the type and size in the evidence.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Canary Wharf to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.