Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →Our frameless fire-rated glazing service covers Greenwich and neighbouring areas such as Blackheath and Canary Wharf, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Whether the building is in central Greenwich or the wider SE10, SE8, SE14, SE13, SE3, SE4 districts, we can survey and quote. We also cover Blackheath, Canary Wharf, Catford. Greenwich sits within our Greater London coverage, alongside Blackheath.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Every quote in Greenwich identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can survey and quote for hotels, healthcare buildings and other building types in Greenwich.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, typically. It also needs more careful site protection.
Building work in Greenwich follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Greenwich depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Greenwich and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.