Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our insulated fire glass service covers Hanworth and neighbouring areas such as Hampton and Feltham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
Whether the building is in central Hanworth or the wider TW13, TW12, TW14, TW11, TW1, TW2 districts, we can survey and quote. We also cover Hampton, Feltham, Sunbury-on-Thames. Hanworth sits within our Greater London coverage, alongside Hampton.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
If an existing frame in a Hanworth building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Hanworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover schools and colleges, blocks of flats and other buildings in Hanworth.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes, in normal conditions. It turns opaque only when heated in a fire.
Building work in Hanworth follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Hanworth and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.