Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →We provide frameless fire-rated glazing in Hanworth and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Frameless glass is exposed during the build. We plan protection until other trades finish.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Our Greater London coverage takes in Hanworth (TW13, TW12, TW14, TW11, TW1, TW2) and the neighbouring towns of Hampton, Feltham, Sunbury-on-Thames. Hanworth is one of the Greater London districts we cover.
We can phase work in Hanworth around residents, staff or pupils, with out-of-hours options.
Every quote in Hanworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover blocks of flats, hotels and other buildings in Hanworth.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Yes, typically. It also needs more careful site protection.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Hanworth follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Hanworth and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.