Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Looking for fire-rated escape route glazing in Hanworth? We survey, supply and install tested fire-rated glazing for offices, hotels and other buildings in and around Hanworth, including the TW13 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Whether the building is in central Hanworth or the wider TW13, TW12, TW14, TW11, TW1, TW2 districts, we can survey and quote. We also cover Hampton, Feltham, Sunbury-on-Thames. We cover Hanworth as part of our Greater London coverage.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
After survey you get a fixed written quote for the agreed scope, so Hanworth budgets are not open-ended.
Every quote in Hanworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Fire-rated escape route glazing applies to many building types in Hanworth, including offices and hotels.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Hanworth confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.