Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · TW5

Fire-Rated Glass Floors across Heston

We provide fire-rated glass floors in Heston and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.

REI 30 – 60TW5England

Quote for Heston

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glass floors in Heston

A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.

  • Coordination with the structural engineer
  • Anti-slip surface treatments within the system
  • Steel support frames to the tested details
  • Horizontal fire-rated rooflights

Before you order fire-rated glass floors: what matters

Slip resistance

Walk-on glass needs an anti-slip finish; it must be one covered by the system.

Rooflights

Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.

Sizes are limited

Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.

Areas we cover around Heston

Our Greater London coverage takes in Heston (TW5, UB2, TW3, TW4, TW7, UB18) and the neighbouring towns of Hounslow, Isleworth, Southall. Heston is one of the Greater London districts we cover.

What every Heston quote includes

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Heston budgets are not open-ended.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Heston building types

Fire-rated glass floors applies to many building types in Heston, including schools and colleges and healthcare buildings.

Questions about fire-rated glass floors in Heston

Can a glass floor be fire-rated?

Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.

Can we see through it?

Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.

Do you work on occupied buildings in Heston?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

How quickly can you survey in Heston?

Survey timing in Heston depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Heston

E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Survey

We visit Heston to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote