Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →We provide fire-rated glass floors in Southall and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Survey visits can be arranged anywhere in Southall, including the UB1, UB2, UB18, W7, UB4, TW5 districts, and in nearby Greenford, Heston, Hayes. Southall is one of the Greater London districts we cover.
Every quote in Southall identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Southall building has no traceable evidence, we say so and price the options rather than guess.
Fire-rated glass floors applies to many building types in Southall, including healthcare buildings and blocks of flats.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in Southall and across Greater London, including the UB1 district and nearby Greenford.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Southall confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.