Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · TW5

Fire-Rated Glazed Screens for Heston buildings

We provide fire-rated glazed screens in Heston and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 120TW5England

Quote for Heston

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glazed screens in Heston

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Integrity or insulating glass to the required classification
  • Integrated fire doors and glazed doorsets
  • Steel, aluminium, timber or frameless frame systems
  • Fire-stopping at head, jambs and sill to the system details

What to check before ordering fire-rated glazed screens in Heston

Acoustic and security needs

Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Areas we cover around Heston

Our Greater London coverage takes in Heston (TW5, UB2, TW3, TW4, TW7, UB18) and the neighbouring towns of Hounslow, Isleworth, Southall. We cover Heston as part of our Greater London coverage.

What you can expect in Heston

Work around occupied buildings

We can phase work in Heston around residents, staff or pupils, with out-of-hours options.

Honest about unknowns

If an existing frame in a Heston building has no traceable evidence, we say so and price the options rather than guess.

Rated systems, not just rated glass

Every quote in Heston identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Building types we cover in Heston

Sector guides below cover offices, retail and leisure units and other buildings in Heston.

Fire-Rated Glazed Screens: Heston questions

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

Do you work on occupied buildings in Heston?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Heston?

Building work in Heston follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Heston

Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Heston confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote