Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →From the TW5 district outwards, we arrange insulated fire glass for buildings across Heston, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Whether the building is in central Heston or the wider TW5, UB2, TW3, TW4, TW7, UB18 districts, we can survey and quote. We also cover Hounslow, Isleworth, Southall. We cover Heston as part of our Greater London coverage.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Heston building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Heston around residents, staff or pupils, with out-of-hours options.
Insulated fire glass applies to many building types in Heston, including retail and leisure units and hotels.
Yes, in normal conditions. It turns opaque only when heated in a fire.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Survey timing in Heston depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Heston follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Heston and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.