Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Fire-rated fanlights and side panels in Westminster is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
We cover Westminster and the surrounding postcode districts, including SW1, SW1A, W1M, SW1X, EC1A, EC1M. Nearby towns we also serve include Pimlico, London, Chelsea. Westminster is one of the Greater London districts we cover.
Every quote in Westminster identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Westminster budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire-rated fanlights and side panels applies to many building types in Westminster, including schools and colleges and public buildings.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Building work in Westminster follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Westminster confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.