Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →From the SW1 district outwards, we arrange fire glazing remedial works for buildings across Westminster, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire glazing remedial works are the repairs and replacements that bring glazed fire-resisting elements back into line with their required performance: replacing unsuitable glass, refitting beads and seals, sealing service penetrations, and replacing frames that cannot be shown to be rated.
Remedial glass and seals must suit the existing frame's evidence. Where that evidence is missing, we raise it before work starts.
Cables and pipes through glazed screens and their surrounds must be fire-stopped with products tested for that application.
We plan remedial programmes around residents, pupils or staff, with phasing and clear communication.
Survey visits can be arranged anywhere in Westminster, including the SW1, SW1A, W1M, SW1X, EC1A, EC1M districts, and in nearby Pimlico, London, Chelsea. We cover Westminster as part of our Greater London coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Westminster building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover schools and colleges, hotels and other buildings in Westminster.
Yes. We prioritise by risk and agree phases with you.
Yes. Send the report and we will price the glazing-related actions item by item.
Building work in Westminster follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Westminster and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.