Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Fire-rated fanlights and side panels in Battersea is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Coverage around Battersea includes the SW11, SW3, SW10, SW4, SW8, SW1 districts and nearby Chelsea, Pimlico, Westminster. Battersea is one of the Greater London districts we cover.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Battersea around residents, staff or pupils, with out-of-hours options.
Every quote in Battersea identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fire-rated fanlights and side panels applies to many building types in Battersea, including retail and leisure units and schools and colleges.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
Survey timing in Battersea depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Battersea confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.