Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SW1

Westminster timber fire-rated screens

Timber fire-rated screens in Westminster is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

E 30 – EI 60SW1England

Quote for Westminster

Tell us what you need. We reply with next steps and a guide price.

What's involved with timber fire-rated screens in Westminster

The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.

  • Over-panels, side panels and borrowed lights
  • Hardwood frames to tested sections and densities
  • Fire glass with the specified intumescent glazing system
  • Fire-stopping to the structure

How we work in Westminster

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Work around occupied buildings

We can phase work in Westminster around residents, staff or pupils, with out-of-hours options.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Key checks for Westminster projects

Beads are part of the rating

Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.

Heritage buildings

Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.

Moisture and movement

Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.

Areas we cover around Westminster

Whether the building is in central Westminster or the wider SW1, SW1A, W1M, SW1X, EC1A, EC1M districts, we can survey and quote. We also cover Pimlico, London, Chelsea. Westminster sits within our Greater London coverage, alongside Pimlico.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

Building types we cover in Westminster

Sector guides below cover retail and leisure units, hotels and other buildings in Westminster.

Questions about timber fire-rated screens in Westminster

Can timber screens be fire-rated?

Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.

Which timbers are used?

Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.

How quickly can you survey in Westminster?

Survey timing in Westminster depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Do you work on occupied buildings in Westminster?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Westminster

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

From enquiry to handover in Westminster

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Westminster and check what the existing frames can accept.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote