Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →From the PE15 district outwards, we arrange fire door vision panels for buildings across March, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
A fire door vision panel is the glazed opening in a fire door that lets people see through it. It is part of the door's fire rating: the glass, beads, glazing seals and the size and position of the opening all have to match the door's test or certification evidence.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
Ordinary float or toughened glass in a fire door vision panel is a serious defect. We replace it with fire-resistant glass compatible with the door.
Survey visits can be arranged anywhere in March, including the PE15 districts, and in nearby Wisbech, Ely, Peterborough. March lies roughly 23 km from Peterborough, within our Cambridgeshire coverage.
If an existing frame in a March building has no traceable evidence, we say so and price the options rather than guess.
Every quote in March identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in March around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire door vision panels applies to many building types in March, including blocks of flats and retail and leisure units.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in March and across Cambridgeshire, including the PE15 district and nearby Wisbech.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in March confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.