Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →If a building in Ely needs fire door vision panels, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
A new aperture can invalidate a door's certification unless the manufacturer's instructions allow it. We check before cutting.
Ordinary float or toughened glass in a fire door vision panel is a serious defect. We replace it with fire-resistant glass compatible with the door.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Whether the building is in central Ely or the wider CB7, CB6 districts, we can survey and quote. We also cover Newmarket, March, Cambridge. Ely lies roughly 40 km from Peterborough, within our Cambridgeshire coverage.
If an existing frame in a Ely building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can survey and quote for offices, retail and leisure units and other building types in Ely.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Yes. We survey and install in Ely and across Cambridgeshire, including the CB7 district and nearby Newmarket.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Ely confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.