Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →For Totton buildings, we supply, replace and check insulated fire glass wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
If an existing frame in a Totton building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Totton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Totton budgets are not open-ended.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
We cover Totton and the surrounding postcode districts, including SO40, SO16, SO15. Nearby towns we also serve include Southampton, Hythe, Eastleigh. Totton lies roughly 6 km from Southampton, within our Hampshire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Insulated fire glass applies to many building types in Totton, including industrial units and retail and leisure units.
Only products approved for external use, usually in a sealed unit with UV protection.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
Yes. We survey and install in Totton and across Hampshire, including the SO40 district and nearby Southampton.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Totton and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.