Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →If a building in New Milton needs insulated fire glass, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We cover New Milton and the surrounding postcode districts, including BH25. Nearby towns we also serve include Christchurch, Bournemouth, Hythe. New Milton is about 25 km from Southampton, the largest town in our Hampshire coverage.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a New Milton building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Insulated fire glass applies to many building types in New Milton, including schools and colleges and care homes.
Yes, in normal conditions. It turns opaque only when heated in a fire.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
Building work in New Milton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit New Milton to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.