Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SE10

Insulated Fire Glass (EI) — Greenwich and SE10

For Greenwich buildings, we supply, replace and check insulated fire glass wherever the fire strategy depends on it, working to the tested system rather than the glass alone.

EI 30 – EI 120SE10England

Quote for Greenwich

Tell us what you need. We reply with next steps and a guide price.

What's involved with insulated fire glass in Greenwich

EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.

  • Handling and installation of heavy panes
  • EI 30, EI 60, EI 90 and EI 120 glass
  • Internal and external-grade build-ups
  • Insulating glass in sealed double-glazed units

Before you order insulated fire glass: what matters

The temperature rule

EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.

How it works

When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.

Thickness and weight

Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Areas we cover around Greenwich

Survey visits can be arranged anywhere in Greenwich, including the SE10, SE8, SE14, SE13, SE3, SE4 districts, and in nearby Blackheath, Canary Wharf, Catford. Greenwich is one of the Greater London districts we cover.

What you can expect in Greenwich

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Rated systems, not just rated glass

Every quote in Greenwich identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Building types we cover in Greenwich

Sector guides below cover retail and leisure units, healthcare buildings and other buildings in Greenwich.

Questions about insulated fire glass in Greenwich

What does EI 60 mean?

The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.

Why is insulated fire glass so much more expensive?

It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.

How quickly can you survey in Greenwich?

Survey timing in Greenwich depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Can you price insulated fire glass in Greenwich from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Greenwich

E 30 – EI 120

Fire-Resistant Glass

Integrity and insulating fire glass supplied and fitted into tested frames.

Learn more →
Process

How a Greenwich job runs

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Greenwich confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote