Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →From the BT1 district outwards, we arrange insulated fire glass for buildings across Belfast, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Coverage around Belfast includes the BT1, BT14, BT15, BT2, BT3, BT12 districts and nearby Newtownabbey, Lisburn, Newtownards. Belfast is the main town we cover in County Antrim.
We can phase work in Belfast around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in Northern Ireland, not a one-size-fits-all approach.
Every quote in Belfast identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
We can survey and quote for offices, hotels and other building types in Belfast.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Survey timing in Belfast depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Belfast to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.