Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Belfast calls for glazing tested to resist fire, our fire-rated escape route glazing service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Our County Antrim coverage takes in Belfast (BT1, BT14, BT15, BT2, BT3, BT12) and the neighbouring towns of Newtownabbey, Lisburn, Newtownards. Belfast is the main town we cover in County Antrim.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Belfast building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Belfast identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover student accommodation, offices and other buildings in Belfast.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Survey timing in Belfast depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Belfast is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Belfast confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.