Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →When a fire strategy, inspection report or building control comment in Newtownards calls for glazing tested to resist fire, our insulated fire glass service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
If an existing frame in a Newtownards building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Newtownards identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Newtownards around residents, staff or pupils, with out-of-hours options.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Whether the building is in central Newtownards or the wider BT22, BT23 districts, we can survey and quote. We also cover Bangor, Belfast, Carrickfergus. Bangor, around 8 km from Newtownards, is the largest town in the same coverage area.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Sector guides below cover public buildings, offices and other buildings in Newtownards.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes. We survey and install in Newtownards and across County Down, including the BT22 district and nearby Bangor.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Newtownards to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.