Learn more →If a building in Epsom needs timber fire-rated screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.
Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Whether the building is in central Epsom or the wider KT17, KT19, KT21, KT9, SM3, SM7 districts, we can survey and quote. We also cover Ewell, Banstead, Sutton. Epsom is about 20 km from Woking, the largest town in our Surrey coverage.
After survey you get a fixed written quote for the agreed scope, so Epsom budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Epsom around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover care homes, hotels and other buildings in Epsom.
Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.
Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.
Building work in Epsom follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Epsom and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.