Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Kent · CT14

Fire-Rated Glazed Screens across Deal

Fire-rated glazed screens in Deal is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

E 30 – EI 120CT14England

Quote for Deal

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Deal: what's included

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

  • Survey and setting-out against the fire strategy drawings
  • Steel, aluminium, timber or frameless frame systems
  • Handover evidence pack
  • Integrated fire doors and glazed doorsets

Areas we cover around Deal

Survey visits can be arranged anywhere in Deal, including the CT14 districts, and in nearby Dover, Ramsgate, Broadstairs. Deal lies roughly 62 km from Maidstone, within our Kent coverage.

Before you order fire-rated glazed screens: what matters

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What every Deal quote includes

Work around occupied buildings

We can phase work in Deal around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Deal identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Deal budgets are not open-ended.

Building types we cover in Deal

Sector guides below cover schools and colleges, hotels and other buildings in Deal.

Fire-Rated Glazed Screens: Deal questions

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

How quickly can you survey in Deal?

Survey timing in Deal depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Which rules apply to fire-rated glazing in Deal?

Building work in Deal follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Deal

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Deal and check what the existing frames can accept.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote