Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · E15

Fire-Rated Glazed Screens for Stratford buildings

From the E15 district outwards, we arrange fire-rated glazed screens for buildings across Stratford, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 120E15England

Quote for Stratford

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Stratford: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Survey and setting-out against the fire strategy drawings
  • Steel, aluminium, timber or frameless frame systems
  • Integrity or insulating glass to the required classification
  • Handover evidence pack

Before you order fire-rated glazed screens: what matters

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

Areas we cover around Stratford

We cover Stratford and the surrounding postcode districts, including E15, E13, E20, E3, E7, E9. Nearby towns we also serve include Bow, Canning Town, Canary Wharf. Stratford is one of the Greater London districts we cover.

What you can expect in Stratford

Rated systems, not just rated glass

Every quote in Stratford identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Stratford building types

Sector guides below cover schools and colleges, blocks of flats and other buildings in Stratford.

FAQs for Stratford

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Do you work on occupied buildings in Stratford?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Can you price fire-rated glazed screens in Stratford from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Stratford

Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Stratford and check what the existing frames can accept.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote