We provide fire-rated glazed screens in South Ockendon and across Essex, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 120RM15England

Quote for South Ockendon

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated glazed screens service includes in South Ockendon

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

  • Survey and setting-out against the fire strategy drawings
  • Handover evidence pack
  • Integrity or insulating glass to the required classification
  • Fire-stopping at head, jambs and sill to the system details

Areas we cover around South Ockendon

Our Essex coverage takes in South Ockendon (RM15, RM20, RM19, RM16, RM17) and the neighbouring towns of Grays, Hornchurch, Dartford. South Ockendon lies roughly 30 km from Southend-on-Sea, within our Essex coverage.

Before you order fire-rated glazed screens: what matters

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Integrity-only screens on escape routes

Building guidance limits where integrity-only glazing can sit on protected escape routes, and in some positions restricts it to above a set height from the floor. Insulating screens are not restricted in the same way, so the route plan often decides the glass.

Which rules apply to fire-rated glazed screens in South Ockendon?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What every South Ockendon quote includes

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so South Ockendon budgets are not open-ended.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Work around occupied buildings

We can phase work in South Ockendon around residents, staff or pupils, with out-of-hours options.

Building types we cover in South Ockendon

Fire-rated glazed screens applies to many building types in South Ockendon, including care homes and hotels.

Fire-Rated Glazed Screens: South Ockendon questions

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Do you work on occupied buildings in South Ockendon?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Can you price fire-rated glazed screens in South Ockendon from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in South Ockendon

Process

From enquiry to handover in South Ockendon

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in South Ockendon confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote