Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Dyfed · SA15

Fire-Rated Glass Floors across Llanelli

From the SA15 district outwards, we arrange fire-rated glass floors for buildings across Llanelli, matching glass, frames and seals to tested evidence rather than guesswork.

REI 30 – 60SA15Wales

Quote for Llanelli

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glass floors in Llanelli

Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.

  • Anti-slip surface treatments within the system
  • Handover evidence
  • Horizontal fire-rated rooflights
  • Tested walk-on fire-rated glass floor systems

What every Llanelli quote includes

Work around occupied buildings

We can phase work in Llanelli around residents, staff or pupils, with out-of-hours options.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Llanelli budgets are not open-ended.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Before you order fire-rated glass floors: what matters

Sizes are limited

Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.

Slip resistance

Walk-on glass needs an anti-slip finish; it must be one covered by the system.

Load and fire together

A glass floor must carry its design load during the fire period. Only systems tested for both should be used.

Areas we cover around Llanelli

Survey visits can be arranged anywhere in Llanelli, including the SA15 districts, and in nearby Gorseinon, Swansea, Ammanford. Llanelli is the largest town in our Dyfed coverage.

Fire glazing rules in Wales

Wales Which rules apply?

Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.

The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.

Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.

Sectors we cover in Llanelli

We can survey and quote for public buildings, offices and other building types in Llanelli.

Fire-Rated Glass Floors: Llanelli questions

How big can a fire-rated glass floor panel be?

Each system sets maximum panel sizes; larger areas are divided by a supporting grid.

What does REI mean?

R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.

Which rules apply to fire-rated glazing in Llanelli?

Llanelli is in Wales, where the Welsh Approved Document B applies to building work and the Regulatory Reform (Fire Safety) Order 2005 covers occupied premises.

Do you work on occupied buildings in Llanelli?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Llanelli

E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

From enquiry to handover in Llanelli

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Llanelli and check what the existing frames can accept.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote