Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →From the RG18 district outwards, we arrange fire-rated glass floors for buildings across Thatcham, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
Whether the building is in central Thatcham or the wider RG18, RG19, RG14 districts, we can survey and quote. We also cover Newbury, Basingstoke, Reading. Thatcham lies roughly 21 km from Reading, within our Berkshire coverage.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Obscured or patterned surfaces can be specified within the system for privacy below.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Every quote in Thatcham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Thatcham around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Fire-rated glass floors applies to many building types in Thatcham, including schools and colleges and blocks of flats.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Thatcham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Thatcham and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.