Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Looking for fire-rated glass floors in Reading? We survey, supply and install tested fire-rated glazing for healthcare buildings, retail and leisure units and other buildings in and around Reading, including the RG1 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
After survey you get a fixed written quote for the agreed scope, so Reading budgets are not open-ended.
If an existing frame in a Reading building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Reading around residents, staff or pupils, with out-of-hours options.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
Glass floors are made to order with longer lead times; we plan early with your contractor.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Whether the building is in central Reading or the wider RG1, RG4, RG30, RG6, RG2 districts, we can survey and quote. We also cover Earley, Wokingham, Crowthorne. Reading is the largest town in our Berkshire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated glass floors applies to many building types in Reading, including healthcare buildings and retail and leisure units.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Survey timing in Reading depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We survey and install in Reading and across Berkshire, including the RG1 district and nearby Earley.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Reading to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.