Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →If a building in Barry needs frameless fire-rated glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Channels at the head have to allow for slab movement without loading the glass.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Our South Glamorgan coverage takes in Barry (CF62, CF63) and the neighbouring towns of Penarth, Cardiff, Caerphilly. Barry lies roughly 11 km from Cardiff, within our South Glamorgan coverage.
After survey you get a fixed written quote for the agreed scope, so Barry budgets are not open-ended.
We can phase work in Barry around residents, staff or pupils, with out-of-hours options.
Every quote in Barry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.
Sector guides below cover retail and leisure units, blocks of flats and other buildings in Barry.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, typically. It also needs more careful site protection.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in Barry and across South Glamorgan, including the CF62 district and nearby Penarth.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Barry and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.