Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →If a building in Feltham needs frameless fire-rated glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Whether the building is in central Feltham or the wider TW13, TW14, TW15, TW6, TW5, TW3 districts, we can survey and quote. We also cover Hanworth, Ashford, Hounslow. Feltham is one of the Greater London districts we cover.
Every quote in Feltham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Feltham around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Feltham budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover schools and colleges, blocks of flats and other buildings in Feltham.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Building work in Feltham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Feltham and across Greater London, including the TW13 district and nearby Hanworth.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Feltham to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.