Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Shropshire · SY1

Fire-Rated Curtain Walling in Shrewsbury, Shropshire

Looking for fire-rated curtain walling in Shrewsbury? We survey, supply and install tested fire-rated glazing for healthcare buildings, offices and other buildings in and around Shrewsbury, including the SY1 postcode district.

E 30 – EI 60SY1England

Quote for Shrewsbury

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated curtain walling in Shrewsbury

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Fire-rated zones within mixed facades
  • Slab-edge fire-stopping and cavity barriers to the design
  • Handover evidence for the building record
  • External-grade fire glass

Before you order fire-rated curtain walling: what matters

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Which rules apply to fire-rated curtain walling in Shrewsbury?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Areas we cover around Shrewsbury

Whether the building is in central Shrewsbury or the wider SY1, SY2, SY3 districts, we can survey and quote. We also cover Wellington, Telford, Rhosllannerchrugog. Telford, around 21 km from Shrewsbury, is the largest town in the same coverage area.

How we work in Shrewsbury

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Shrewsbury budgets are not open-ended.

Work around occupied buildings

We can phase work in Shrewsbury around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Shrewsbury identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Sectors we cover in Shrewsbury

Fire-rated curtain walling applies to many building types in Shrewsbury, including healthcare buildings and offices.

FAQs for Shrewsbury

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Which rules apply to fire-rated glazing in Shrewsbury?

Building work in Shrewsbury follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

How quickly can you survey in Shrewsbury?

Survey timing in Shrewsbury depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Shrewsbury

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Shrewsbury job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Shrewsbury and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote