Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →When a fire strategy, inspection report or building control comment in New Milton calls for glazing tested to resist fire, our fire glass replacement service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We identify the existing glass from its marks, measure the opening, make the area safe and fit the correct replacement. If the original product is no longer made, we source an alternative covered by the frame's evidence or advise on the right next step.
When the original glass is no longer available, the replacement must be covered by the frame's evidence or an assessment.
A broken pane can be a cut hazard and a gap in compartmentation. We can make it safe on the first visit while the replacement is cut.
Repeated breakage can point to frame movement, door slamming or impact from trolleys. We look at the cause.
Whether the building is in central New Milton or the wider BH25 districts, we can survey and quote. We also cover Christchurch, Bournemouth, Hythe. Southampton, around 25 km from New Milton, is the largest town in the same coverage area.
After survey you get a fixed written quote for the agreed scope, so New Milton budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire glass replacement applies to many building types in New Milton, including care homes and offices.
Look for an etched or printed mark in a corner of the pane. Send us a photo with the approximate size.
Yes. Single panes can be replaced on their own, provided the replacement is compatible with the frame's evidence.
Building work in New Milton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in New Milton and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.