Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →For Greenwich buildings, we supply, replace and check fire door vision panels wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
We photograph each panel before and after and note the glass marks, so your fire door records stay complete.
A new aperture can invalidate a door's certification unless the manufacturer's instructions allow it. We check before cutting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Coverage around Greenwich includes the SE10, SE8, SE14, SE13, SE3, SE4 districts and nearby Blackheath, Canary Wharf, Catford. We cover Greenwich as part of our Greater London coverage.
Every quote in Greenwich identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Greenwich budgets are not open-ended.
If an existing frame in a Greenwich building has no traceable evidence, we say so and price the options rather than guess.
Fire door vision panels applies to many building types in Greenwich, including retail and leisure units and offices.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Survey timing in Greenwich depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Greenwich follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Greenwich and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.