Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →When a fire strategy, inspection report or building control comment in Greenwich calls for glazing tested to resist fire, our wired glass replacement service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Wired glass replacement means removing old Georgian or polished wired glass from doors, screens and panels and fitting modern fire-resistant glass that keeps the fire rating while meeting today's impact safety expectations. Wired glass holds together in a fire because of the mesh, but plain wired glass usually lacks an impact safety classification and can cause serious injuries when broken by impact.
Doors, side panels and low-level glazing in busy corridors, sports halls and schools are usually replaced first.
Wired glass breaks into sharp pieces held by wire, and the wire weakens the glass. In doors and low-level panels it is a common source of hand and arm injuries.
Old frames may not have evidence for modern fire glass. We assess them and recommend frame replacement where the evidence cannot be established.
Survey visits can be arranged anywhere in Greenwich, including the SE10, SE8, SE14, SE13, SE3, SE4 districts, and in nearby Blackheath, Canary Wharf, Catford. Greenwich is one of the Greater London districts we cover.
If an existing frame in a Greenwich building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Greenwich budgets are not open-ended.
Every quote in Greenwich identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for blocks of flats, schools and colleges and other building types in Greenwich.
It can provide integrity in the right frame, typically for 30 minutes and sometimes longer in tested systems, but it does not insulate, and plain wired glass usually lacks an impact safety classification.
Clear modern integrity or insulating fire glass with an impact classification, compatible with the frame.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Greenwich to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.