Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Fire-rated escape route glazing in Archway is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
We cover Archway and the surrounding postcode districts, including N19, N6, NW5, N4, N8, N7. Nearby towns we also serve include Holloway, Muswell Hill, Chalk Farm. We cover Archway as part of our Greater London coverage.
Every quote in Archway identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Archway around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Archway building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover schools and colleges, hotels and other buildings in Archway.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Building work in Archway follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Archway to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.