Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Looking for insulated fire glass in Archway? We survey, supply and install tested fire-rated glazing for offices, student accommodation and other buildings in and around Archway, including the N19 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Our Greater London coverage takes in Archway (N19, N6, NW5, N4, N8, N7) and the neighbouring towns of Holloway, Muswell Hill, Chalk Farm. We cover Archway as part of our Greater London coverage.
We can phase work in Archway around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Archway building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Insulated fire glass applies to many building types in Archway, including offices and student accommodation.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes. We survey and install in Archway and across Greater London, including the N19 district and nearby Holloway.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Archway to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.