Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Archway buildings, we supply, replace and check fire-rated glazed doors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
Self-closing devices and correct gaps are part of the performance. We set them at installation and record them.
Residential blocks in England over 11 metres need regular fire door checks under the Fire Safety (England) Regulations 2022; glazed doors are included.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Our Greater London coverage takes in Archway (N19, N6, NW5, N4, N8, N7) and the neighbouring towns of Holloway, Muswell Hill, Chalk Farm. We cover Archway as part of our Greater London coverage.
After survey you get a fixed written quote for the agreed scope, so Archway budgets are not open-ended.
We can phase work in Archway around residents, staff or pupils, with out-of-hours options.
Every quote in Archway identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for retail and leisure units, healthcare buildings and other building types in Archway.
Yes. They need fire-resistant glass of the type and thickness tested, fitted with the specified beads and seals.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Yes. We survey and install in Archway and across Greater London, including the N19 district and nearby Holloway.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Archway to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.