Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the EH1 district outwards, we arrange fire-rated escape route glazing for buildings across Edinburgh, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Whether the building is in central Edinburgh or the wider EH1, EH2, EH3, EH7, EH9, EH6 districts, we can survey and quote. We also cover Musselburgh, Kirkcaldy, Dunfermline. Edinburgh is the largest town in our Edinburgh and the Lothians coverage.
We can phase work in Edinburgh around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Edinburgh building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Sector guides below cover hotels, public buildings and other buildings in Edinburgh.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Yes. We survey and install in Edinburgh and across Edinburgh and the Lothians, including the EH1 district and nearby Musselburgh.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Edinburgh to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.