Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Our fire-rated glazed doors service covers Edinburgh and neighbouring areas such as Musselburgh and Kirkcaldy, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
After survey you get a fixed written quote for the agreed scope, so Edinburgh budgets are not open-ended.
We can phase work in Edinburgh around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Opening forces, vision panel zones and contrast need to work with accessibility guidance as well as fire.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Survey visits can be arranged anywhere in Edinburgh, including the EH1, EH2, EH3, EH7, EH9, EH6 districts, and in nearby Musselburgh, Kirkcaldy, Dunfermline. Edinburgh is the main town we cover in Edinburgh and the Lothians.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
We can survey and quote for offices, schools and colleges and other building types in Edinburgh.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Yes, some steel, aluminium and timber doorsets are tested with large or full-height glazing. The glass must be the type and size in the evidence.
Yes. We survey and install in Edinburgh and across Edinburgh and the Lothians, including the EH1 district and nearby Musselburgh.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Edinburgh confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.